New security systems technology
13.9.2024
New technology for home and business anti theft and fire prevention
-
❤ shop perimeter security system
25.4.2024
Shop new technology solar power wireless outdoor detector burglar alarm security systems
-
❤ BUSINESS : shop online for fire alarm system
25.4.2024
fire alarm system shop online complete professional fire alarm security systems
-
Perimeter Security Detectors
8.12.2023
Perimeter Security Detectors are outdoor intrusion sensors. There are optical infrared beams sensor and active infrared Motion Sensor. Beams Sensor is installed on fence, windows or wall to protect the entrance. Motion Sensor is installed to protect importance place and monitor the area.
-
HST fire alarm system manufacturer
8.12.2023
HST brand fire detectors are manufactured by Kaiwei fire system manufacturer. Kaiwei is professional fire alarm system manufacturer. Their products include conventional fire alarm system, alarm control panel, smoke detector, gas sensor, heat detector, CO alarm.
-
Driveway Intrusion Alert Security System Solar Beams Detection
8.12.2023
Outdoor Siren strobe for alert of driveway intrusion detection system.
The package is used for house or business perimeter security.
It is newest technology wireless solar powered beams system and solar-powered siren strobe.
Leading package includes 1x 3 beams with LCD calibrator solar-powered infrared detector and 1 pc siren strobe solar-powered outdoor installation with 2 pcs remote controller.
One siren strobe can equip with maximum 32 wireless beams and remote controllers.
Details of driveway intrusion alert neighbor and police notice security system
Wireless beams detector updated with LCD calibrator and electricy power supply and battery rechargeable power jack. Infrared Distance 120m, Wireless emitting distance 1km
-
Beam break alert 4G app monitor alarm notify
8.12.2023
Perimeter Security Solution with app monitor wireless solar power beam break alert system.
Easy install the beam transmitter and receiver terminals on fence, courtyard, garden, driveway to create invisible light wall. When someone intrudes the light wall, the beam sensor will send alarm report to wireless receiver, the app monitor control panel.
So, intrusion will be notified on app on ios and android app notification.
App monitor alarm control panel has TCP/IP version (RJ45 interface), 2G version and 4G version.
TCP/IP version has app monitor only.
2G or 4G version can set alarm notification phone number and can send SMS and voice call for alarm report.
-
Audio visual alarm conventional fire alarm warning device Sound light fire warning device Conventional fire alarm system [TCSG5228F]Wireless fire alarm solar power perimeter security systems shop$10.50Shop security service equipment fire alarm burglar alarm systems onlineFire Alarm Systems Category Shopping, Fire Alarm Store Complete Fire Security Material
8.12.2023
-
Fire Alarm Control Panel CK1016 Conventional Fire linkage
8.12.2023
This fire alarm control panel meets NFPA requirement. It should be installed, commissioned and maintained by suitably qualified service personnel.
-
Fire Fighting Gas extinguish Manual release station
8.12.2023
The manual release button is connected with fire fighting panel. There are three buttons on the station, one is START button, another is STOP button and RESTORE button. When the START button is pressed, it will trigger fire fighting panel to release gas extinguishing for fire fighting. RESTORE button is used to restore the start button.
-
Manual Call point 2-wire Fire alarm systems
8.12.2023
SB-116 Manual call point 2-wire Operates by Advanced MCU Expert Algorithm Software.
The conventional manual call point is designed for fire alarm systems and security alarm systems
It is with pull down plate for safe and easy press to call at emergency condition and easy to restore after the alarm.
It can be reset by using the key to open the case without breaking the glass.
It is compatible with all the conventional fire alarm control panel.
Each fire zone should have at least one manual fire alarm button. The distance from any location in a fire zone to the nearest manual fire alarm button should not be more than 30m.
The manual fire alarm button is set at the entrance and exit of public places activity rooms.
-
Gas detector with solenoid valve fire alarm systems
8.12.2023
This package includes gas detector and solenoid valve 1/2" (If you need other size 3/4" etc. please leave comment for us)
GA543-A AC Powered Plug-In Combustible Gas Detector
General
The gas detector is designed for single station use or for connecting to fire alarm or security alarm panel. Small and compact, the design and color makes it
ideal for use in the home, small commercial properties, and recreational vehicles. It is intended to detect leakage of natural gas (methane gas), town gas, and bottled gas (propane gas), coal gas. The unit is designed for AC Powered plug-in applications. The gas detector can bemounted high (for methane gas) or low (for propane (LPG) gas). It is equipped with a sturdy metal mounting bracket for quick, easy, and secure installation.
-
Smoke alarm 24V 2 wire conventional Fire Detection
8.12.2023
Conventional photoelectric smoke alarm 24V 2 wire
EN54 Certificated 2 wire conventional photoelectric smoke sensor
The fire detector should be tested and maintained regularly following NFPA 72 requirement for fire alarm and fire detection systems.
It uses a state of the art optical sensing chamber. It can be used with most conventional fire alarm control panel.
The detector include a tamper resistant capability that prevents their removal from the bracket without the use of a tool.
Before testing notify the proper authorities that the smoke detector system is undergoing maintenance and will temporarily be out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms. Detectors must be tested after installation and as part of periodic maintenance.
-
Smoke and Heat Detector FT-143 Relay output 4-wire
8.12.2023
Smoke and Heat Detector FT-143 Relay output 4-wire
The detector is photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel.
This device may help your family safe from any fire accident occur during late at night or early in the morning.
-
Smoke Detector 4-wire with relay output DC powered
8.12.2023
4-Wire Smoke Detector with Relay output DC powered YT-142
The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.
The default condition for the relay is normally open (NO). It can be adjusted to Normal close (NC)
-
Vehicle gas detector DC12v gas alarm with manipulator
8.12.2023
This package includes gas detector and manipulator
GA543 DC power 12V Gas Detector. Let us know what size for your manipulator
General
The gas detector is designed for single station use or for connecting to fire alarm or security alarm panel. Small and compact, the design and color makes it
ideal for use in the home, small commercial properties, and recreational vehicles. It is intended to detect leakage of natural gas (methane gas), town gas, and bottled gas (propane gas), coal gas. The unit is designed for AC Powered plug-in applications. The gas detector can bemounted high (for methane gas) or low (for propane (LPG) gas). It is equipped with a sturdy metal mounting bracket for quick, easy, and secure installation.
-
waterproof 24V conventional fire alarm horn strobe sounder
8.12.2023
This is kind of manual outdoor sound and flash strobe siren optional, it is suitable for fire, medical, patrol etc, It used high quality LED flash lights and Ultra sound loudness piezoelectric device, with high conversion efficiency for photoacoustic, electricity.
-
Fire Alarm Control Panel 2 zones Conventional Fire communication
8.12.2023
Conventional Fire Alarm Control Panel 2 zones
It meets requirement of EN54 parts 2&4
It is 2 zones Mini fire alarm control panel works with Maximum 60 detectors and call points.
It can work with Maximum 31 slave fire panel by RS485 communication and show their panel and zone No. alarm or fault status.
Each panel can work with maximum 16 sounders with maximum 1A /24V power supplied.
-
Relay output smoke alarm AC power smoke detector
8.12.2023
Relay output smoke alarm AC power smoke detector
Functions:
1. Smoke detector works with 220V AC power supply. Work indicator light is on during normal working status. When alarm, the alarm indicator light up and sound alarm.
2. Smoke alarm has relay output with N/C or N/O contact output. When there is no smoke, you can choose power off reset or automatic reset.
3. The smoke detector has installing base and can be well installed easy.
-
gas detector co sensor ac power plugin two in one home security
8.12.2023
Carbon monoxide and flammable gas compound detector home environment security kits. Sensor is for sensing both CO and flammable gas. It is installed in kitchen room etc.
-
Conventional Reflected Beam Smoke Detection
8.12.2023
Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings.
Their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches.
With only one device to install and align, these single-ended optical beam solutions save you time and money on open-area and high-ceiling applications.
The firebeam protection system includes a motorised head unit containing an infra-red transmitter and receiver, a ground level controller and prism reflector.
Making use of the prism reflector the returned infra-red beam is analysed for smoke contamination and registers a fire condition at a pre-determined level.
At ground level the controller unit is used to make operational adjustments. The standard protection system covers a range of 5 to 40 meters.
-
Fire Alarm Button 2-wire conventional fire alarm system
8.12.2023
2-wire conventional fire alarm push button
product: manual call point break glass
Specification: 9~32VDC Volts 2 wires call point
Material: ABS
Color: Red
Brand: HST
Model: SB106
Size: W89mm ,H93mm, D26mm
SPECIFICATIONS
Operating Voltage Range: 9~32VDC Volts
Nominal Operating Resistance: 300Ω
Relay Contact Ratings: 2A/30VDC
Operating Humidity Range: 95% RH, Non-condensing
Operating Temperature Range: -10°C to 50°C (14°F to 122°F)
Dimensions: W89mm ,H93mm, D26mm
Base Dimensions: W87mm ,H87mm, D31.5mm
Weight: Net Weight 125g (with base)
Colour/Case Material: Red/ ABS
-
Alarm Bell 6" 110dB Sound Fire Signal System
8.12.2023
Alarm Bell 6" 110dB Sound Fire Signal System
-
Fire Alarm Signal Light for Fire Evacuation
8.12.2023
sound strobe conventional sounder siren alarm DC24V
SPECIFICATIONS
Working voltage: 16VDC to 30VDC.
Alarm Current: ≤ 50mA.
Ambient temperature: -10℃ to +55℃.
Ambient humidity: ≤95%RH.
Sound level of alarm : ≥100dB.
Flash Intensity: ≥75CD
Flash Period: <1S
Life of flash light: >40000times
Dimensions: 133mm×115mm×50mm
L ×W×D(With base)
Weight: 141g
-
Meian Technology home security systems manufacturer
8.12.2023
Focus brand security and smart home and business burglar alarm, fire detection security systems are manufactured by Meian Technology Co.,Ltd.
Meian Co.,Ltd. is China top security systems manufacturer. Products include commercial alarm system, home alarm system, AI video alarm, smart home, security SaaS solutions.
-
Latest Home Security Alarm System
8.12.2023
Complete basic set latest home security system with video surveillance security camera.
The package including alarm panel with ip camera and door sensor, intrusion detector PIR, remote controller and RF card.
The alarm panel is 4G and TCP/IP RJ45 network or WIFI network.
It adopts latest technology and with APP for remote operation and monitoring.
Features of alarm panel:
Brilliant color screen display, menu operation.
Full voice prompt, full touch glass panel.
32 wireless defense zones, two-way wireless communication.
Built-in GSM module, support GPRS data transmission.
Built-in TCP/IP module, support network data transmission.
16-way electrical control, electrical switch timing control. Real-time monitoring of battery undervoltage of wireless detectors; regular arming/disarming.
RF card swipe to arm and disarm;
remote off-site arming, disarming, and on-site monitoring.
Mobile APP remote operation control.
Computer IE remote operation control.
Set 32 defense zones that can be associated with video through the APP.
Built-in rechargeable lithium battery 3.7V 1600mAh
433MHz/868MHz frequency optional, ASK wireless networking.
-
Hengbo security technology perimeter security equipment
8.12.2023
HB brand solar powered perimeter security systems are made by Hengbo security technology Co.,Ltd.
Hengbo focuses on providing perimeter security solutions that are easy to install and maintain. All kinds of solar wireless intrusion detectors are very convenient to solve the problem of security protection of outdoor and wilderness property.
Solar powered perimeter security systems is designed with multiple technologies and IP66 rating to ensure the reliability of security systems and the service life of products.
HB brand solar power alarm system installation guide and manual can be found at burglar alarm Vedard Security Technology provides free technical support and after sales service for all the products life time.
-
Environment Security Components
8.12.2023
Environment Security Component is a security device to monitor environment safety and avoid pollution, on fire or poisoning. It can be wired to home security system or work stand-alone.